Setting the Accumulator to 0
When dealing with loading 0 into the Accumulator, there's several ways to do it.
3E00LDA,0Traditional way to set A to 0
AFXORAAnything xor itself is 0
97SUBAA-A=0
The downside to the above options is that they also affect the flags. However, they are only 1 byte long not 2 and are both 3 T-states faster.
Inverting A
If inverting A, i.e. swapping each bit from 1 to 0 and vis-versa then instead of XOR 0xFF
use
CPL
instead. It's both faster, 1 byte and that's all that instruction does.
EEFFXOR0xFFA=A XOR 0xff
2FCPLThis instruction does exactly the same thing and nothing else!
The downside is that CPL
does not affect the flags whilst XOR
does.