This the multi-page printable view of this section.Click here to print.

Return to the regular view of this page.

DD_READ_ID

Read a sector identifier

Table of Contents

Function AddressDescription
DD_READ_ID 016FRead a sector identifier

Synopsys

Read a sector identifier

Entry Parameters

Register Content
C Unit 0 or 1
D Logical track, 0 base
IX Address of XDPB

Exit Parameters

If OK:
Carry true
A = sector number from identifier
Otherwise:
Carry false
A = Error code
Always:
HL = Address of result buffer in page 7